Filter Results By:

Products

Applications

Manufacturers

Showing results: 406 - 420 of 598 items found.

  • PXI General Purpose 2A Relay Module 19xDPST

    40-132-202 - Pickering Interfaces Ltd.

    Pickering Interfaces 40-131/132 modules are a range of low cost, general purpose electromechanical relay cards. They are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.

  • PXI General Purpose 2A Relay Module 16xSPST

    40-132-101 - Pickering Interfaces Ltd.

    Pickering Interfaces 40-131/132 modules are a range of low cost, general purpose electromechanical relay cards. They are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.

  • PXI General Purpose 2A Relay Module 16xDPST

    40-132-102 - Pickering Interfaces Ltd.

    Pickering Interfaces 40-131/132 modules are a range of low cost, general purpose electromechanical relay cards. They are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.

  • PXI General Purpose 2A Relay Module 32xSPST

    40-132-201 - Pickering Interfaces Ltd.

    Pickering Interfaces 40-131/132 modules are a range of low cost, general purpose electromechanical relay cards. They are capable of switching voltages up to 300VDC/250VAC and current up to 2A. They are suitable for use where reed relay based switching cards do not have sufficient voltage or current carrying capability. Applications include the switching of medium power AC and DC loads, or slave switching larger relays, contactors or solenoids. Connections are made to the card via a front panel mounted 78 pin D-Type connector plug.

  • Active FET Probe Kit 1.2 GHz, 10x, ±40 V

    CT4121 - Cal Test Electronics

    The CT4121 is a compact FET probe with very high input resistance and low input capacitance. With a 1.2 GHz bandwidth, this probe is ideal for timing analysis or troubleshooting high speed logic circuits, for design verification of disk drives, as well as for wireless and data communication design. The CT4121 can measure up to ±40 V (DC + AC peak). Compatible with oscilloscopes from all major manufacturers, the probe is powered by the included 9 V battery or direct from the oscilloscope using the included USB power lead.

  • FPGA Testing

    Silicon Turnkey Solution, Inc.

    The secret to our success in the FPGA testing field is the STS hammer file, a proprietary test methodology based on our experience testing thousands of unique FPGA designs. The hammer file is designed to program the FPGA to its maximum combination and block configuration and then tests the completely programmed FPGA for full dynamic, DC and at-speed AC performance. Power and transient tests are also conducted under worst-case populated configurations. Application-specific usage configurations are also used to assist in generating the worst-case electrical specification limits at worst-case environmental use.

  • ESS Performance Test System

    Bloomy Controls, Inc.

    The Energy Storage System (ESS) Performance Test System is used to evaluate, test, and certify the performance of energy storage systems up to 2MW. The system is a configurable platform with over 200 channels of simultaneously measured AC and DC voltages and currents, environmental temperatures, airflow, and communications. Intuitive software provides real-time monitoring and analysis of power, energy and efficiency to adhere with industry standards. The test system interfaces hardware such as load banks, and controls the ESS to simulate utility applications such as peak shaving and frequency regulation.

  • 40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger

    SD750100G - Zhejiang Sandi Electric Co., Ltd

    40kw High Efficiency AC/DC Power Supply Charger 100-750VDC Charging Rectifier 100A Battery Charger is for DC battery system charging station. With three-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. 50-500Vdc output voltage range optional, suitable for all types of batteries.FeaturesProduct Introduction:SAND AC/DC Charger is specially developed for DC chargers module. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase or single phase, DC output voltage range from 100 to 750VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger module.Unique function:● High efficiency over the full load range, full load efficiency greater than 95.5%● Wide output voltage range, 100-750VDC, suitable for a wide range of Lithium and lead acid battery● 5-inch LCD touch screen, easy to operate● Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operateMain features:● Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc.● Three phase active power factor correction technology, reduces the harmonic interference to the grid● Dual DSP design, achieve the full digital control, less components means high reliability● Wide input voltage range, allows operation in most poor grid conditions● Soft start charging and soft shutdown minimize the impact on the battery.● Input, output have protective circuit breaker switch● Module adopts hot pluggable design, which is convenient for maintenance.● CAN/RS485 interface (Optional)SpecificationModel SD750100GAC input Input system Three phases + PEVoltage range 280Vac ~500VacRated voltage 440VacFrequency range 50Hz/60HzMaximum current <74AITHD (total harmonic distortion) <5%DC output Output power 40KWVoltage range 50-750Vdc ( can set)Constant power output voltage range 400Vdc-750VdcOutput current range (A) 100A ( 1~100A can set)Output current limit 1-100A continuously adjustableSteady voltage precision <±0.5%Steady current precision ≤±1% (rated range of 20% ~ 100% for output load)Load regulation rate ≤±0.5%Startup overshoot ≤±3%Peak-to-peak value noise ≤1% (200~1000V, 0~20MHz)Display Indication Light Green LED: normal operation,Yellow LED: alarm, Red LED: failureDisplay language EnglishDisplay 5’ LCD touch screenPower factor and THD Power factor ≥0.90 Full-load output power of @20%~50%≥0.98 Full-load output power of @50%~100%≥0.99 Full-load output power, input nominal voltage and frequency of @100%THD ≤5% Full-load output power of @50%~100%Protection function input overvoltage Protection Over Under Voltage automatic shutdown and restart when voltage return normalOutput overvoltage protection Over Under Voltage automatic shutdown and restart when voltage return normalOver-temperature protection Automatic shutdown. Automatic restart when the temperature return to normalShort circuit protection Automatic shutdown and lock, need power off to restart to unlockEfficiency Under Rated input voltage ≥95.2%

  • Low Power Programmable AC Source

    61600 Series - Chroma Systems Solutions, Inc.

    Power:500VA (61601)1000VA (61602)1500VA (61603)2000VA (61604)4000VA (61605)Voltage range: 0-150V/0-300V/AutoFrequency: 15Hz 1000HzCompact size and weight attributable to advance PWM technologyBuilt-in PFC, provide input power factor over 0.98 (full load)AC+DC output mode for voltage DC offset simulationProgrammable slew rate setting for changing voltage and frequencyProgrammable voltage, current limitOne-key recall for 9 different voltage and frequencyLow output impedance for testing IEC 61000-3-2 ( 61605 )Comprehensive measurement capability, V, Irms, Ipk, Inrush, P, Q, S, PF, CF of current and etc.High output current crest factor, ideal for inrush current testingTurn on, turn off phase angle controlTTL signal which indicates ON/OFFAnalog programming interface3 units combined to 3-phase power outputEasy-use software for operation and ON/OFF testOptional GPIB and RS-232C interfaceFull protection: OP,OC,OV and OT protection

  • EDFA

    SPA-10G-32 - Hangzhou Softel Optic Co., Ltd.

    *Single/dual input for choice, built in optical switch for dual input, the switching  power can be set by thebutton in the front panel or by web snmp. *Output adjustable by buttons in the front panel or web snmp, the range  is down 4dBm *Max multi 32 port, with built in1310/1490/1550/1270/1577/WDM,max total output 38 dBm *Standard RJ 45 port for remote control, we can provide output contract and web manager for choice, and also plug-in snmp hardware can be reserved for update. *With laser key to turn on/off the laser.*With RF test function. *Adopts JDSU Pump laser*Led displays the working condition of the machine*Dual power hot plug power supply for choice, 90V~250V AC or -48V DC

  • Programmable/Direct Reading Attenuators

    ERAVANT

    Is a dual function direct reading and programmable rotary vane type attenuator for use in millimeterwave systems across the standard WR-03 frequency range of 220 to 330 GHz. The attenuator is an ideal piece of equipment in waveguide systems where a broad direct reading of attenuation is required. The default mode of operation is manual direct reading. In manual mode, the attenuation is adjustable with the large knob and the digital LCD screen displays the current attenuation value. The LCD screen is powered by an internal rechargable battery, which is charged via the 2.5mm DC jack by a provided DC to AC adapter. The 2.5mm DC jack also provides power to the stepper motor, encoder and internal microprocessor for the programmable mode function. The user can quickly switch to programmable mode by connecting the powered-up attenuator to a computer with the USB Type B port. In programmable mode, the attenuation is finely adjusted with a precision stepper motor by the internal microprocessor via user-entered serial port commands from the computer.

  • Gauss Meters

    PCE Instruments

    A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.

  • PXI 8x4 1-Pole 10A Matrix With Loop-Thru

    40-551-101 - Pickering Interfaces Ltd.

    Used for switching inductive/capacitive loads up to 10A with 125VDC/250VAC hot switching and 400VDC/250VAC cold switching. X and Y connections are made via a 20-way GMCT plug, this module with loop-thru has an additional 20-way GMCT plug for module-to-module connection. This version of the 40-551 may be expanded to larger matrix sizes using cabling to daisy-chain the X and Y signals Power Matrix Modules are intended for switching heavy AC or DC loads or for slaving large external relays, contactors and solenoids. Suitable for applications requiring switching of either mains voltage or direct current.

  • Digital Tesla Meter

    HT208 - Rinch Industrial Co.,Limited

    Model HT208 digital teslameter is controlled by the SCM,which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’sperson. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value,As mT or Gs unit of display can be change over,Measuring range of 200mT or 2000mT can be choosed,and others that as reseting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours

  • Test Compliance

    MX CTS Series - AMETEK Programmable Power, Inc.

    A growing number of electronic products manufactured today have to meet international regulatory requirements for emissions and immunity. This is particularly true for products sold in the European community as well as a growing list of countries in the Far East. The California Instruments MXCTS System provides a cost-effective test solution aimed at verifying higher power product compliance to a number of AC and DC related harmonized test standards. The MXCTS system offers many of the same features and capabilities of the California Instruments CTS Series product line already in use at many EMC labs around the world.

Get Help